KVM over IP Module
5.5.6 Date / Time
Figure 5-28 Date / Time
This link refers to a page, where the internal real-time clock of the IP-KVM can be set up. You
have the possibility to adjust the clock manually, or to use a NTP timeserver. Without a
timeserver, your time setting will not be persistent, so you have to adjust it again, after
IP-KVM loses power for more than a few minutes. To avoid this, you can use a NTP
timeserver, which sets up the internal clock automatically to the current UTC time. Because
NTP server time is always UTC, there is a setting that allows you to set up a static offset to get
your local time.
Warning
There is currently no way to adjust the daylight saving time automatically. So you
have to set up the UTC offset twice a year properly to the local rules of your country.